Dissolved Oxygen Probe Accessories
- (4)
- (1)
- (3)
- (1)
- (1)
- (1)
- (2)
- (1)
- (2)
- (5)
- (1)
- (2)
- (2)
- (1)
- (3)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (2)
Filtered Search Results
METTLER TOLEDO Zero-Current Gel O2, 3 x 25ml
Zero-Current Gel O2, 3 x 25ml.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
ENDRESS & HAUSER INC LIQUILINE M CM42
NC3301699 LIQUILINE M CM42
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Hach Company Hach Recharge Kit - 4 Pre-Filled Cartridges with Premounted Membranes for Orbisphere C1100 Ozone Sensors (33051-xT cap)
Hach rechargeable kit containing four pre-filled sensor cartridges with premounted membranes, designed to service Orbisphere C1100 ozone sensors that use the 33051-xT cap. The kit provides the consumables and maintenance accessories needed to replace sensor cartridges and help maintain measurement accuracy.
- Contains four pre-filled sensor cartridges with premounted membranes.
- Includes replacement o-rings and cleaning tools for cartridge maintenance.
- Restores sensor assembly consumables to maintain measurement performance.
- Supplies multiple replacement cartridges to reduce downtime.
- Requires matching cap type; verify cap compatibility prior to installation.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Cole-Parmer Oakton waterproof DO meter replacement probe with 25-ft cable
These are replacement probes for dissolved oxygen and biological oxygen demand for Oakton DO/BOD oxygen meters.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sigma Aldrich Fine Chemicals Biosciences DuolinkR In Situ PLAR Prob
DuolinkR In Situ PLAR Prob
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sigma Aldrich Fine Chemicals Biosciences DuolinkR In Situ PLAR Prob
DuolinkR In Situ PLAR Prob
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. DO Probe W/VP,12x225mm With VP Connection - Ingold
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Measurement principle: amperometric / polarographicPressure resistance measurement: 0.2 – 6 bar absoluteMechanical pressure resistance: max. 12 bar (174.0 psi) absoluteMeasuring temperature range: 0 – 80°c (32 – 176°f)--Temperature range: -5 – 140°C (23 – 284°F)-- Temperature compensation: automatic with builtin RTD--Cable connection: vario pin (ip68)-- O-Ring material: Viton, silicone (FDA approved)-- Membrane material: Teflon / silicone / Teflon (reinforced with steel mesh)--Quick disconnect interior body: standard--Cathode: pt--Anode: ag--Guard ring: no--Detection limit: 6ppb--Accuracy: 1% or 4ppb--Response time @25°C (air to n2): 98% of--final value <90s-- Sensor signal in ambient air (25°C): 40 – 110na-- Residual signal in oxygen-free medium: <0.1% of the signal in ambient air.--Max. Flow error: less than or equal to: 5%-- Certification: EHEDG, 3a, 3.1b (en 10204.3.1b)
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. DO Probe PTFE,12x320mm Mettler
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Cathode platinumAnode silverPolarization 675mvOutput 40 to 70na in air at 25cTemperature 0 to 60c sterilization to 130cStability 2 or readout per week at constant pressure temp 30cLinearity better than 03 of readoutPressure 60psi maximumConnector 4 pin Bendix--Material welded parts 316L stainless steel
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Broadley James Corporation REPLACEMENT CARTIDGE 4/PK
Kit, Four Cartridge; Contains everything required to replace four membrane cartridges on a 12mm OxyProbe; Includes: One 25mL bottle of electrolyte, Four membrane cartridges, Four sets of internal o-rings
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bioanalytical Systems Inc EC RDE-2-CELL TOP
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Cell Top; PTFE; For RDE-2 voltammetry cell *Does not ship to Puerto Rico
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bioanalytical Systems Inc EC C2 CELL TOP
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Cell Top; PTFE; For C-3 or CGME voltammetry cell *Does not ship to Puerto Rico
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Hach Company Dissolved Oxygen AccuVac Ampules, LR, pk/25
For determination of low range Dissolved Oxygen by the Indigo Carmine Method, using AccuVac Ampules. Hach Method 8316. Range: 8 - 1000 µg/L O2. Package of 25 ampules
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Hach Company Dissolved Oxygen AccuVac Ampules, High Range, pk/25
For determination of Dissolved Oxygen by Hach methods 8166 and 8333. Ranges: 0.3 - 15.0 or 1 - 40 mg/L O₂. Pack of 25 ampules.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Hach Company Replacement Membranes for Dissolved Oxygen Probe
Replacement membranes (package of two) for sensION+ 5130 (article number LZW5130.97.0002) and sensION (article number 5197000) DO Probes.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Hach Company Replacement LDO Sensor Cap for LDO101 Luminescent/Optical Dissolved Oxygen Probes
For use with Hach IntelliCAL LDO optical dissolved oxygen probes. Includes iButton and sensor cap.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More